Reduziert!

JA 595W N-Type Bifacial Glas-Glas Rahmen Silber TS

Artikelnummer: JAM72D-40-595-LB-TS-MC4

Ursprünglicher Preis war: 75,45 €Aktueller Preis ist: 72,73 €.

Auf Lager

Gewicht32,5 kg
Größe233,3 × 113,4 × 3 cm
Garantie

12 Jahre

Lieferzeit

sofort

Lager

Rotterdam (NUR Versand)

Bestellbar ab

10 Stück

Artikelnummer: JAM72D-40-595-LB-TS-MC4 Kategorien: ,

JA 595W N-Type Bifacial Glas-Glas Rahmen Silber TS

Restmenge, solange Vorrat reicht. Mengenrabatt auf Anfrage per Email möglich!

Produktmerkmale:

Höhere Stromerzeugung – bessere LCOE.
N-Typ mit sehr niedrigem LID.
Bessere Reaktion auf schwache Beleuchtung.
Besserer Temperaturkoeffizient.
Mit 12 Jahren Produktgarantie und 30 Jahren Garantie auf die lineare Leistungsabgabe.

The rated electrical characteristics, lsc is within +/- 5 % and Voc is within +/- 3 % of measured values at Standard Test Conditions, but for the Pmax, it is within +/- 3%. Standard Test Conditions: 1000W/m2 lrradiance, 25 C Gell Temperature and 1.5 Air Mass.
Under normal conditions, the photovoltaic modules may experience conditions that produce more current and/or voltage than reported at Standard Test Conditions. Accordingly, the values of short circuit current, lsc, and open circuit voltage, Voc, marked on modules should be multiplied by a factor of 1.25 when determining component voltage ratings, conductor capacities, fusing sizes, and size of controls connected to the module output.
Voltages are additive when modules are connected directly in series, and modules currents are additive when modules are connect­ ed directly in parallel, as illustrated in Figure 4.
Modules with different electrical characteristics must not be connected directly in series.

The maximum number of modules that can be connected in a series string must be calculated in accordance with applicable regulations in such a way that the specified maximum system voltage (The maximum system voltage of JA Solar Modules is DC 1500V according to the safety appraisal of the IEC61730.) of the modules and all other electrical DC components will not be exceeded in open-circuit operation at the lowest temperature expected at the PV system location.
Correction factor for the open-circuit voltage can be calculated based on the following formula: Cvoc=1-ßvocx(25-T). T is the lowest expected ambient temperature at the system location. ß(%/ C) is the temperature coefficient of the selected module Voc (refer to corresponding datasheet).
An appropriately rated over-current protection device must be used when the reverse current could exceed the value of the maximum fuse rating of the modules. An over-current protection device is required for each series string if more than two series strings are connected in parallel, in Figure 4.

JA 595W N-Type Bifacial Glas-Glas Rahmen Silber TS

Fragen zu diesem Produkt? Sie können auch im Forum diskutieren!
Besuchen Sie unser Webinar oder Roadshows!

Datenblatt

JAM72D40 575-600 LB
JA Solar – Integrated Tracability System

Versand Hinweis

Zusätzliche Option bei Spedition:
*Kleine LKW + 180€
*LKW mit Hebebühne +160€
Spediteure liefert meistens mit kleine LKW und Hebebühne, aber nicht immer.
Durch Buchung dieser Zusatzoption wird es in dem Fall garantiert. 
Bitte Zusatzoption als Notiz bei Bestellung oder per Email angeben.
Bei Container ist diese Option nicht buchbar.

Passendes Zubehör:

JA 595W N-Type Bifacial Glas-Glas Rahmen Silber TS